62.5 KVA Silent Diesel Generator available for rent in Dubai
62.5 KVA Silent Diesel Generator - view 2
62.5 KVA Silent Diesel Generator - view 3
PerkinsGeneratorsIn Stock

62.5 KVA Silent Diesel Generator for Rent in Dubai & UAE

Exactly 50 kW on the nameplate — the size specified when an engineer, not a contractor, wrote the requirement.

62.5 KVADieselSilent CanopyThree Phase

The 62.5 KVA silent diesel generator looks like an odd number until you note that it is precisely 50 kW at 0.8 power factor. That is why it appears on consultant drawings and tender documents so often — the electrical load was specified in kilowatts and converted. If your specification says 50 kW, this is the set that matches it exactly, on a four-cylinder Perkins 1104A-44TG1 that is a step up in engine size from the 60 KVA.

Capacity
62.5 KVA / 50 kW
Supply
Three Phase
Noise
66 dB(A) at 7 m
Runtime
approx 14 hrs per tank

62.5 KVA Generator Rental Price

Daily, weekly and monthly rates are available for the 62.5 KVA Silent Diesel Generator, with fuel, delivery and installation quoted separately so you can see exactly what you are paying for. Monthly hire works out cheapest per day. Tell us your dates and site location and we will send a fixed written quote.

What a 62.5 KVA Generator Will Run

These are real loads we have supplied this set for, not theoretical maximums. A 62.5 KVA generator gives 50 kW of continuous power at the standard 0.8 power factor. Size your job so the running load sits between 50 and 80 percent of that, which leaves headroom for the surge when motors start. If you are unsure, send us your equipment list and we will size it for you at no cost.

Typical loads a 62.5 KVA generator can power
Load type What this set handles
Specified 50 kW loadMatches a 50 kW essential-services board exactly
Building standbyLifts, chillers, pumps and emergency lighting
Industrial processProduction line with mixed motor loads
Event powerLarge stage plus full catering village
Cold storage7 x refrigerated containers

62.5 KVA Silent Diesel Generator Specifications

Full technical specification
Power output62.5 KVA
Continuous power50 kW
Fuel typeDiesel
PhaseThree Phase
Voltage415 V / 240 V
Frequency50 Hz
EnginePerkins 1104A-44TG1 turbocharged
AlternatorStamford-type brushless with AVR
CoolingWater Cooled
StartingElectric start with key
Fuel tank160 litres
Fuel consumption11.7 L/h at 75% load
Runtime per tankapprox 14 hours at 75% load
Noise level66 dB(A) at 7 metres
EnclosureFull soundproof canopy
Outlets2 x 200A three-phase, 4 x 63A, 4 x 32A
Dimensions (L x W x H)2,800 x 1,180 x 1,620 mm
Dry weight1300 kg

What Is Included

  • Serviced, load-tested and inspected before every hire
  • Same-day delivery across Dubai and next-day UAE-wide
  • Daily, weekly, monthly and project rates
  • 24/7 breakdown response with unit swap-out
  • Delivered with a full tank; refuelling service available
  • Free load sizing advice before you book
  • Earth rod, cables and distribution board available
  • Operator and generator attendant on request

Best Suited To

  • Tender and consultant specifications written in kW
  • Utility and DEWA substation temporary supply
  • Industrial process loads with a fixed kW rating
  • Etihad Rail and infrastructure corridor works
  • Standby for buildings with a 50 kW essential-services board

62.5 KVA Compared With the Sizes Either Side

Picking a generator one size too small costs you downtime; one size too large costs you fuel and risks wet stacking. This is how the 62.5 KVA stacks up against its neighbours in our fleet.

Comparison of adjacent generator sizes
Specification60 KVA62.5 KVA (this page)70 KVA
Continuous power48 kW50 kW56 kW
FuelDieselDieselDiesel
SupplyThree PhaseThree PhaseThree Phase
EnginePerkins 1103A-33TG2 turbochargedPerkins 1104A-44TG1 turbochargedPerkins 1104A-44TG2 turbocharged
Fuel burn at 75%11.2 L/h11.7 L/h13.1 L/h
Tank / runtime150 L / approx 13 hrs160 L / approx 14 hrs170 L / approx 13 hrs
Noise at 7 m66 dB(A)66 dB(A)67 dB(A)
Dry weight1250 kg1300 kg1400 kg

Where We Deliver the 62.5 KVA Generator

We run our own transport, so a 62.5 KVA set can be on your site the same day almost anywhere in Dubai and next day across the rest of the Emirates. Remote sites, farms, desert plots and island projects are all routine for us. These are the areas we cover most often:

Not on the list? We cover the whole of the UAE — see all service areas or ask us about your location.

62.5 KVA Generator Rental — Questions We Get Asked

Why is it rated 62.5 KVA and not 60 or 65?

Because 62.5 KVA at the standard 0.8 power factor is exactly 50 kW. Consultants specify loads in kilowatts, so this rating exists to match a 50 kW requirement precisely rather than approximately.

Is it different from a 60 KVA in practice?

Yes — it uses the larger four-cylinder Perkins 1104A-44TG1 rather than the three-cylinder 1103 in the 60 KVA, so it is a genuinely bigger machine, not just a re-rated one.

How much does it cost to rent a 62.5 KVA generator in Dubai?

Rates depend on hire duration, delivery point and whether you need fuel and an operator included. Daily, weekly and monthly rates are all available and monthly hire is by far the cheapest per day. Send us your dates and location and we will come back with a fixed written quote, with no obligation.

What load will a 62.5 KVA generator actually carry?

A 62.5 KVA set delivers 50 kW of continuous power at the standard 0.8 power factor. As a rule, size your generator so the running load sits between 50 and 80 percent of that figure, which leaves room for the surge when motors start. Tender and consultant specifications written in kW is a typical fit.

Do you deliver a 62.5 KVA generator across the UAE?

Yes. We deliver to Dubai, Sharjah, Ajman, Al Ain, Umm Al Quwain, Ras Al Khaimah and Fujairah, including remote sites, farms and desert locations. Same-day delivery is normally possible within Dubai when you book before midday.

Is fuel included with the generator hire?

We deliver the set with a full tank as standard. After that you can refuel yourself or add our scheduled refuelling service, which we usually recommend for continuous running so nobody has to watch the gauge. The 160 litre tank on this unit gives roughly 14 hours at 75 percent load.

What happens if the generator breaks down?

Call us and we respond 24/7. Every set is serviced and load-tested before it leaves our yard, but if a fault does occur on site we attend and, where it cannot be fixed quickly, we swap the unit so your work does not stop.

Need a 62.5 KVA generator on site today?

Tell us the load, the dates and the location. We will confirm the right size, give you a fixed price and get the set delivered — usually the same day within Dubai.